English Việt Nam
PRODUCT CATEGORY
NEW NEWS
View all
INFORMATION
Showtimes in theaters
Exchange
Quotes
Gold price information
Lotto Results
ADVERTISING
 
Tủ Trung Tâm Chữa Cháy Khí FS5200E

Fire Extinguishing Control Panel FS5200E

The Fire Extinguishing Control Panel is designated for fire protection, monitoring and control of systems for active extinguishing – gas, powder, aerosol, water, etc.

   DETAILED DESCRIPTION:

PRODUCT DESCRIPTION

FS5200E is already certified by EVPU!!!

The Fire Extinguishing Control Panel is designated for fire protection, monitoring and control of systems for active extinguishing – gas, powder, aerosol, water, etc. After processing the signals from the automatic fire detectors and/or manual call points the Control Panel makes commands to the executive devices for extinguishing, sound-light signalers, air conditioning and ventilation devices, etc. The Control Panel could exchange data with a repeater, PC or another intelligent device via RS 485 interfaces.

Functional data
– Control of the lines, the controllable inputs and outputs for Fault condition and automatic resetting
– Control of the lines for removed fire detector and automatic resetting
– Option for setting the evacuation time from 0 to 5 minutes
– Option for setting the time when the extinguishing device is switched on from 10 seconds to 5 minutes
– Built-in sounder for Fire condition and Fault condition with the option for switching off
– Built-in clock for astronomic time
– Test modes and setting option
– Power independent archive of 100 events registered by the Control Panel, containing the type, date and time of the event

 

Technical data

FIRE ALARM LINES: 3
– with extinguishing control: 2
– without extinguishing control: 1

MAXIMUM NUMBER OF FIRE DETECTORS IN A LINE: 32
CONTROLLABLE INPUTS FOR:
– manual extinguishing activation: 1
– extinguishing keeping: 1
– extinguishing disable: 1
– mode selection: 1
– monitoring the extinguisher outflow: 1

CONTROLLABLE OUTPUTS RELAY (24±3)V DC:
– for sounders in Fire condition: 1
-for sounders in Extinguishing status: 1
-for Extinguishing switching on: 1

RELAY OUTPUTS SWITCHING 3À/125V AC, 3A/30V DC:
– for Fire condition: 3
– for Extinguishing: 3
– for Fault condition: 3

OUTPUTS OPEN COLLECTOR TYPE: 3

SIGNALIZATION OF REGISTERED EVENTS:
– sound: built-in sounder
– light: LED
– text messages: LCD display, backlit

POWER SUPPLY:
– mains: 220/230V AC, 50/60 Hz
– backup battery: 2x12V DC, 12 Ah

MAXIMUM CURRENT TO EXTERNAL DEVICES: 2,5 A at (24±3)V DC
OPERATING TEMPERATURE: minus 5oC to 40oC
RELATIVE HUMIDITY: (93±3)% at 40oC
DIMENSIONS: 450x355x115 mm
WEIGHT (EXCLUDING THE BACKUP BATTERY): 6,6 kg

   DOWNLOAD:
CONTACT ORDER
OTHER PRODUCTS
Rescue Vehicle SIDES VS6000-France.
6000/SSW2
6000/VAD/C/RED
 
ONLINE SUPPORT
Technical Support
Hotline: 0838 404 901
Business Support
Do Huy Duong: 090 3848 989
PARTNER
STATISTICS
Online: 45
Total access: 3078053
Copyright 2008 - 2012 by PCCC4-10 company - Designed by EATech Corp