English Việt Nam
PRODUCT CATEGORY
NEW NEWS
View all
INFORMATION
Showtimes in theaters
Exchange
Quotes
Gold price information
Lotto Results
ADVERTISING
 
6400 Fire Alarm Control Panel

6400/DCN - Display and Control Node

Display and controls of the Algo-Tec™ 6400 system are via 6400/DCN’s. All the functions of the 6400/DCN are accessed via a modern styled hinged lockable door, moulded from polycarbonate, finished in storm grey with a clear display viewing window, optional polished solid brass or brushed stainless steel finishes for recess mounting only. When opened, the door allows access to the system controls.

Two full duplex RS232 ports that are site configurable for baud rate/handshaking are available for site programming and interfacing to BMS, Colour Graphics or Pager systems.


6400/LPN - Loop Processing Node

The 6400/LPN nodes process the loop data from the field devices, communicate with other network nodes, and implement the cause and effects program for local and network fire signals. Sounder circuits and auxiliary change-over contacts are also controlled from the 6400/LPN.


6400/DCN/LPN - Combined DCN and LPN (2 nodes)

The 6400/DCN and 6400/LPN are combined within a common enclosure. The appearance is the same as the 6400/DCN and uses the 6400/LPN back box to accommodate the cabling.

   DETAILED DESCRIPTION:

6400 Series Common Specification

Temperature Range

0 - 40°C.

Maximum Humidity

85% Non-Condensing.

Working Voltage

21.5 - 30V dc.

Secure Network

Dual channel RS485 fault tolerant communications network for up to 100 nodes.
3 wire loop (2 Data & 0V), maximum 1km between nodes.

Node Power Supply

Fault monitored dual path 24V dc from 6400/BC range PSU 4 wire plus 2 wire (2 Primary Power, 2 signals) (2 Sec. Power).

Total Node Load

Maximum load to a 6400/LPN or 6400/DCN/LPN is 6A.

 
6400/DCN

Standby Load
(Mains Fail Condition)

210mA.

Alarm Load
(Mains Fail Condition)

390mA.

Display

Quarter VGA Backlit Graphics LCD

Zones

100 Zone Fire indicators, plus common ‘FIRE’ indicator. Expandable to 800

Printer

40 column low noise thermal printer

Nodes

The 6400/DCN counts as one node on the network

RS232 Ports

Two full duplex RS232 ports for site programming, BMS, Colour Graphics or pager system interfacing

Auxiliary Output Supply

Two sets of 24V dc output terminals. Total load 1A

Common Fire Output
(fire station)

24V dc fully monitored output rated at 20mA. 1K EOL

Common Fault Output
(fire station)

24V dc fully monitored output rated at 20mA. 1K EOL.

Dimensions (mm)

440(W) x 385(H) x 104(D)

Approvals

LPCB Certificate No: 201ad/01
EC Certificate No: 0832-CPD-1434
Relevant Standard: EN 54-2


6400/LPN

Standby Load
(Mains Fail Condition)

250mA (2 loop) 310mA (4 loop)

Alarm Load
(Mains Fail Condition)

480mA (2 loop) 540mA (4 loop)

Analogue Addressable Loops

2 to 4 loops, each with 127 address capacity per loop. Total 6400/LPN capacity 4 loops, 508 addresses.

Total Loop Load

600mA per loop including all loop connected devices.

Nodes

The 6400/LPN counts as one node on the network.

Programmable Alarm Outputs

8 monitored 24V dc sounder circuits 1A rated. 47K EOL. 6 non monitored - clean changeover contacts (1A rated @24V).
Expansion modules available to increase alarm output capability. Up to 127 programmable alarm outputs per loop using loop output devices. Total node load 6A.

Auxiliary Output Supply

Four sets of 24V dc output terminals. Total load 1A.

Common Fire Output
(fire station)

24V dc fully monitored output rated at 20mA. 1K EOL. Dedicated Clean Changeover contacts (1A rated @24V)

Common Fault Output
(fire station)

24V dc fully monitored output rated at 20mA. 1K EOL. Dedicated Clean Changeover contacts (1A rated @24V)

Software Input Switches

Class change, bomb alert. Plus four additional non-dedicated inputs for day/night mode, etc

Dimensions (mm)

440(W) x 385(H) x 144(D).

Approvals

(2 loop)
LPCB Certificate No: 201ad/02
EC Certificate No: 0832-CPD-1435
Relevant Standard: EN 54-2 & 4.

(4 loop)
LPCB Certificate No: 201ad/03

EC Certificate No: 0832-CPD-1436

Relevant Standard: EN 54-2 & 4.


6400/DCN/LPN

Overview

Combined 6400/DCN and 6400/LPN nodes within a common enclosure. The full specification for a 6400/LPN applies plus DCN controls.

Standby load
(Mains Fail Condition)

380mA (2 loop) 440mA (4 loop).

Alarm Load
(Mains Fail Condition)

770mA (2 loop) 830mA (4 loop).

Nodes  

The 6400/DCN/LPN counts as TWO nodes on the network.

Dimensions (mm)

440(W) x 385(H) x 144(D).

Approvals

(2 loop)
LPCB Certificate No: 201ad/04
EC Certificate No: 0832-CPD-1437
Relevant Standard: EN 54-2 & 4

(4 loop) LPCB Certificate No: 201ad/05
EC Certificate No: 0832-CPD-1438
Relevant Standard: EN 54-2 & 4.

6400 Schematic

 
   DOWNLOAD:
CONTACT ORDER
OTHER PRODUCTS
CHEC 3600 / CX / CXT
VHEM 500 / CX / CXT
Input-Output Device FD7203 – 10 inputs / 16 outputs
 
ONLINE SUPPORT
Technical Support
Hotline: 0838 404 901
Business Support
Do Huy Duong: 090 3848 989
PARTNER
STATISTICS
Online: 26
Total access: 2614495
Copyright 2008 - 2012 by PCCC4-10 company - Designed by EATech Corp