Tủ Trung Tâm Báo Cháy 1 Loop 6100
  • Cost Effective Single Loop Panel
  • High Capacity Loop - 192 Addresses
  • Algo-Tec™ 6000PLUS Protocol
  • Surface and Recessed Mounting
  • Easy to Install
  • Reduced False Alarms
  • Enhanced Performance
  • On Site Flexibility
  • Designed to EN 54-2 & 4
   MÔ TẢ CHI TIẾT:

The Protec Algo-Tec™ 6100 is an interactive digital addressable fire detection and alarm system ideally suited for small and medium sized buildings such as shops, hotels and offices. The control panel is designed and manufactured by Protec to comply with EN 54-2 & 4. The control panel is suitable for surface or recessed mounting with a moulded polycarbonate enclosure finished in storm grey.

The 6100 control panel is equipped with a high capacity Algo-Tec™ digital addressable data loop, with up to 192 addresses. In addition to the Algo-Tec™ 6000PLUS sensors, interfaces and manual call points the loop can also support loop powered SOUNDERS, VISUAL ALARM DEVICES and OPTICAL BEAM DETECTORS. Additionally a 6300 Loop Powered Repeat Display can be connected directly to this loop, resulting in reduced cabling requirements, simplified installation and associated cost savings.

Rated Voltage

100 to 240V ac rms

Rated Frequency

50 to 60 Hz

Rated Current

600mA rms

Working Voltage

21.5 - 29V dc

Temperature Range

0 - 40°C

Maximum Humidity

85% Non-condensing

IP Rating

IP30

Battery Type

2 x 12V 3.3Ah sealed lead acid

Standby Load
(Mains Fail Condition) 

22mA

Maximum Alarm Load
(Mains Fail Condition)

56mA panel
600mA loop
200mA conventional alarms (100mA per alarm output)
150mA auxillary 24V output
20mA fire-link

Display

Backlit liquid crystal display 4 lines of 20 characters

Digital Addressable Loops

1 loop, with 192 address capacity
Algo-Tec™ 6000PLUS Protocol

Total Loop Load

600mA including all loop connected devices

Zones

32 Zones, 16 with LED indication, plus general fire indicator

Integral Charger

1A dc switch mode, temperature compensated

Integral Battery

2 x 12V 3.3Ah sealed lead acid

Alarm Outputs

2 monitored conventional sounder circuits
(100mA per output maximum)   

Up to 192 alarm outputs using loop output devices.

Global Fire Outputs

1 set of non-monitored changeover contacts
(1A @ 24V dc) operating on any fire

Alarm Load

600mA loop, 100mA per conventional alarm output

Fault Monitoring

Fully fault monitored to EN 54-2 & 4

Fault Output

Single pole changeover contacts
(1A rated @ 24V dc)

Auxiliary Output Supply

24V dc fused at 150mA

Common Fire Output
(fire station)

24V dc fully monitored output
(requires end of line module SF4165759)

Communications Interface

USB 2.0 (Type A male to Type B male connection lead required - 2 Metres maximum length)

Dimensions (mm)

228(W) x 345(H) x 111(D)

Weight  

1.5kg (excluding batteries)

Applicable Standards

EN 54-2 : 1997 + A1 : 2006
EN 54-4 : 1998 + A1 + A2

Alarms

In addition to loop powered sounders and beacons, 2 fully monitored alarm outputs are provided at the panel for alternative wiring arrangements.

Auxiliary Contacts

One set of global fire, and one set of fault changeover contacts.

Controls and Display

All the functions of the modern styled Control Panel are accessed by entering the user access code. The controls are SILENCE, SOUND ALARMS, RESET and ACCEPT plus navigation push buttons to enable access to the user menu facilities. The control panel display consists of a 4x20 character liquid crystal display, twin common fire LED indicators, 16 separate zonal fire LED’s, power on, pre-alarm, system fault, common fault, test and disablement LEDs.

Liquid Crystal Display

The 80 character liquid crystal displaywill under normal quiescent conditions display the current date and time with the option to also display a 40-character user’s message such as site name.
In an alarm or fault condition the LCD will display the device, address and zone number and up to 20 characters of user definable location text, programmable on site using Protec 6100 windows based software.

Device Location Text

Windows based text software is supplied free of charge to our clients to enable you to enter the location text on to the disk supplied and hand to our commissioning engineer for loading into the panel during commissioning. This simple process allows you more flexibility enabling you to make any last minute changes and speed up the entire process.

Power Supply

The 6100 control panel is supplied with an integral 1A dc switch mode charger and accommodates two 12V 3.3 Ah sealed lead acid batteries.

On Site Programming

The Protec Algo-Tec™ 6100 system is on site programmable. All of the commissioning configuration data can be entered and/or backed up using the Protec 6100 windows based programming software via a PC. This feature enables the system to be re-configured and checked prior to attending site simplifying commissioning works on site, enabling text amendments to be carried out whilst on site and providing an invaluable remote backup should the need arise.

 
   TẢI TÀI LIỆU:
LIÊN HỆ ĐẶT MUA
SẢN PHẨM KHÁC
Cáng Cứu Hộ Dưới Nước
Nút Nhấn Khẩn 3000/MCP
OPH 120
 
HỖ TRỢ TRỰC TUYẾN
Hỗ trợ kỹ thuật
HOTLINE: (028) 3840 4901
Hỗ trợ kinh doanh
Mr. ĐỖ HUY DƯƠNG: 0903.848.989
ĐỐI TÁC
THỐNG KÊ
Đang online: 7
Tổng truy cập: 3078364
Copyright 2008 - 2012 by PCCC4-10 company - Designed by EATech Corp